Kev piav qhia
CDL / CDLF lub teeb ntsug multistage centrifugal twj tso kua mis yog lub twj tso kua mis uas tsis yog tus kheej-priming ntsug multistage centrifugal twj nrog tus qauv tsav. Lub cev muaj zog ncej txuas ncaj qha nrog lub twj tso kua mis los ntawm kev sib txuas ntawm lub taub hau twj tso kua mis. Lub rub qws ntsia liaj qhov rooj kho lub siab lub tog raj kheej thiab qhov ntws ntawm lub taub hau twj tso kua mis thiab lub qhov dej nkag thiab qhov hluav taws xob. CDL / CDLF ntsug multistage centrifugal twj tso kua mis tuaj yeem nruab nrog cov kev tiv thaiv ntse raws li kev xav tau, txhawm rau tiv thaiv lub twj tso kua mis kom qhuav, theem poob, overload thiab lwm yam.
Cov xwm txheej ua haujlwm
Cov kua uas nyias, huv si, tsis-flammable thiab tsis muaj cov khoom siv los yog fibers. (Yog xav paub ntxiv, koj tuaj yeem rub tawm cov qauv phau ntawv lossis hu rau cov neeg ua haujlwm muag)
Kua kub: chav tsev kub hom -15 degree rau +70 degree
Hom dej kub -15 degree rau +120 degree
Ambient kub: Max. +40 degree
Qhov siab: siab tshaj 1000m
Lub cev muaj zog
Lub cev muaj zog yog kaw tag, cua txias bipolar txheem lub cev muaj zog.
Kev tiv thaiv chav kawm: IP55
Rwb thaiv tsev: F
Tus qauv voltage: 50Hz: 1x{2}} / 240V
3x200-220/346-380V
3 x 220-240/380-415V
3 x380-415V
Tib-theem motors muaj nyob ntawm 0.37KW-2.2KW
Kev sib txuas hom
● DIN Flange
● Txiav ferrule sib koom
● Cov yeeb nkab xov
●Oval Flange
CDL / CDLF lub teeb ntsug multistage centrifugal twj tso kua mis yog cov khoom siv ntau yam, tuaj yeem siv los ua lub twj tso kua mis ib leeg, tuaj yeem siv rau hauv kev lag luam nrog cov khoom siv txhawb zog. Muaj peev xwm thauj tau los ntawm cov kais dej thiab cov kua dej ua haujlwm thiab lwm yam xov xwm sib txawv, haum rau qhov sib txawv ntawm qhov kub thiab txias, ntws thiab siab ntau yam, CDL yog tsim rau cov kua uas tsis muaj corrosive, CDLF haum rau cov kua dej me ntsis.
● Kev siv dej: dej cog pom thiab kev thauj mus los, dej cog thaj chaw dej, supercharging ntawm lub ntsiab, supercharging ntawm cov tsev siab.
●Industrial pressurization: txheej txheem dej system, tu system, kev kub siab flushing system, tiv thaiv hluav taws.
● Kev lag luam ua kua: cua txias thiab cua txias tshuab, boiler feedwater thiab condensing systems, tshuab cuab yeej, acids thiab alkalis.
● Kev kho dej: ultrafiltration system, rov qab osmosis system, distillation system, separator, pas dej da.
● Irrigation: ua liaj ua teb irrigation, sprinkler irrigation, drip irrigation.

Yam khoom
|
Kev piav qhia |
CDL 150 |
CDL 200 |
||||||||||||||||
|
Tus nqi ntws [m³ / h] |
1 |
2 |
3 |
4 |
5 |
8 |
10 |
12 |
15 |
16 |
20 |
32 |
42 |
65 |
85 |
120 |
150 |
200 |
|
Tus nqi khiav [l/s] |
0.28 |
0.56 |
0.83 |
1.1 |
1.39 |
2.2 |
2.78 |
3.3 |
4.17 |
4.4 |
5.6 |
8.9 |
11.7 |
18 |
24 |
33 |
41.6 |
55.6 |
|
Flow ntau [m³ / h] |
0.4-2 |
1-3.5 |
1.2-4 |
1.5-7 |
3-8 |
5-12 |
5-13 |
7-16 |
8-22 |
8-22 |
10-28 |
16-40 |
25-55 |
30-80 |
50-110 |
60-150 |
80-180 |
100-240 |
|
Flow range [l/s] |
0.11-0.56 |
0.28-0.97 |
0.33-1.1 |
0.42-1.9 |
0.83-2.22 |
1.4-3.3 |
1.4-3.61 |
1.9-4.4 |
2.2-6.1 |
2.2-6.1 |
2.8-7.8 |
4.4-11.1 |
6.9-15.3 |
8.3-22.2 |
13.8-30.5 |
16.7-41.7 |
22-50 |
27.8-66.7 |
|
MAX.pressure [bar] |
21 |
23 |
22 |
21 |
23 |
21 |
22 |
22 |
22 |
22 |
23 |
29 |
30 |
22 |
17 |
16 |
16 |
16 |
|
Lub cev muaj zog [kW] |
0.37-2.2 |
0.37-3 |
0.37-3 |
0.37-4 |
0.37-5.5 |
0.75-7.5 |
0.75-7.5 |
1.5-11 |
1.1-15 |
2.2-15 |
1.1-18.5 |
1.5-30 |
3.0-45 |
4.0-45 |
5.5-45 |
11-75 |
11-75 |
18.5-110 |
|
Tcmp [degree] |
-15~+120 |
|||||||||||||||||
|
MAX.efficiency[%] |
44 |
46 |
54 |
57 |
64 |
62 |
68 |
63 |
70 |
66 |
69 |
73 |
75 |
76 |
77 |
74 |
73 |
79 |
|
Hom |
||||||||||||||||||
|
CDL |
· |
· |
· |
· |
· |
· |
· |
· |
· |
· |
· |
· |
· |
· |
· |
· |
· |
· |
|
CDLF |
· |
· |
· |
· |
· |
· |
· |
· |
· |
· |
· |
· |
· |
· |
· |
· |
· |
· |
|
CDL Tube kev sib txuas |
||||||||||||||||||
|
DIN Flange |
DN 25 |
DN 25 |
DN 25 |
DN 32 |
DN 32 |
DN40 |
DN40 |
DN 50 |
DN 50 |
DN 50 |
DN 50 |
DN 65 |
DN 80 |
DN100 |
DN100 |
DN125 |
DN125 |
DN150 |
|
Oval Flange |
G1 |
G1 |
G1 |
G1¼ |
G1¼ |
G1½ |
G1½ |
|
|
|
|
|
|
|
|
|
|
|
|
CDLF Pipe kev sib txuas |
||||||||||||||||||
|
DIN Flange |
DN 25 |
DN 25 |
DN 25 |
DN 32 |
DN 32 |
DN40 |
DN40 |
DN 50 |
DN 50 |
DN 50 |
DN 50 |
DN 65 |
DN 80 |
DN100 |
DN100 |
DN125 |
DN125 |
DN150 |
|
Txiav ferrule sib koom |
DN 32 |
DN 32 |
DN 32 |
DN 32 |
DN 32 |
DN 50 |
DN 50 |
DN 50 |
DN 50 |
DN 50 |
DN 50 |
|
|
|
|
|
|
|
|
Cov yeeb nkab xov |
ZG1¼ |
ZG1¼ |
ZG1¼ |
ZG1¼ |
ZG1¼ |
ZG 2 |
ZG 2 |
ZG 2 |
ZG 2 |
ZG 2 |
ZG 2 |
|
|
|
|
|
|
|
|
Oval Flange |
G1 |
G1 |
G1 |
G1¼ |
G1¼ |
G1½ |
G1½ |
|
|
|
|
|
|
|
|
|
|
|
Cim npe nrov: Cdl / cdlf series lub teeb ntsug multistage centrifugal twj tso kua mis, Tuam Tshoj cdl / cdlf series lub teeb ntsug multistage centrifugal twj tso kua mis manufacturers, lwm tus neeg, Hoobkas