Cov nta ntawm cov hluav taws xob zaus hloov kho

 

 

variable frequency converter

Cov haujlwm tshwj xeeb:

  • Tshwj xeeb rau cov khoom siv dej, ua tiav cov haujlwm
  • Txee installation, muaj zog nthuav dav
  • Tuaj yeem paub ib-rau-ob txoj kev tswj hom

 

Txhim khu kev qha ua tau:

  • Ua kom ntseeg tau ntev ntev kev ua haujlwm ntawm cov khoom
  • Kev Tswj Xyuas Zoo Tswj Xyuas Kom Tau Khoom Zoo
  • Kev ywj pheej Cua Ciav tsim, cov qauv ntsuas kub
  • Cov Cheebtsam Cov Qauv, Cov Kev Txhim Kho Cov Lus Qhia

 

Kev tiv thaiv zoo meej:

  • Cov khoom siv overcurrent, overvoltage, overheating, luv nqi hluav taws xob
  • Lub cev muaj zog ua cov tshuaj tiv thaiv luv luv
  • Dej siab siab siab siab siab, tsis tshua muaj siab, dej tsis muaj zog idling, kev tiv thaiv kev tiv thaiv
  • Dej Tsis Txaus Reset Muaj Zog

 

Kev nthuav dav dav:

  • Txheem dual-channel sib txuas lus
  • Txheem Dual-Channel Relay
  • Ntau qhov sib txuas tswj thiab cov tswv tsev tshuaj xyuas

 

Cov yam ntxwv tswj

 

 

  • Tswj hom: V / f tswj
  • Pib Torque: 1Hz 100%
  • Kev Hloov Kho Ceev: 1:20
  • Tus ceev qhov tseeb: ± 1. 0%
  • Tus nqa khoom zaus: {0. 5khz ~ 16kHz
  • Tshaj muaj peev xwm: 150% rated tam sim no rau 60s, 180 rated tam sim no rau 1s

 

Lus hauv kev tswj hwm

 

 

  • Cov lus qhia voltage: 220V / 380V; FLOMPOMUPOM Kev hloov kho: ± 15%
  • Kev Qhuab Qhia: 50 / 60HZ, FONLESSTA REMAZE: ± 5%
  • Cov Txiaj Ntsig Voltage: {{0- Cov tswv yim hluav taws xob, tsis ua yuam kev tsawg dua 5%
  • Cov Khoom Siv Zaus: V / F: {0-100 hz
  • Kev Ua Haujlwm Community: 3 channel: Vaj huam sib luag ua haujlwm tau muab, tswj lub davhlau ya nyob twg, tuaj yeem hloov pauv hauv ntau txoj kev
  • Zaus los: Cov ntaub ntawv chaw, Vaj Huam Sib Luag Pulse Potentietietiet, analog voltage teeb tsa, analog kev sib txuas lus, thiab lwm yam. Hloov tau nyob rau hauv ntau txoj kev
  • Lub Zog Hluav Taws Xob: 5V / 10V / 24V Muab Hluav Taws Xob Hluav Taws Xob, siv cov ntsuas feem ntau
  • Cov tswv yim tawm tswv yim: 2 cov lus qhia digital cov chav kawm; 1 Module cov tswv yim davhlau ya nyob twg; 2 relay tso tawm; 2 Kev Sib Txuas Lus Sib Tham

 

Cov haujlwm yooj yim

 

 

variable speed drive pump

  • Ua-hauv PID: tuaj yeem paub yooj yim paub txog-lub voj tswj system
  • AVR muaj nuj nqi: Thaum cov Grid Voltage hloov, nws tuaj yeem cia li ua kom cov zis hluav taws xob tas li
  • OverVoltage thiab overspeed poob: cia txwv qhov tam sim no thiab voltage thaum ua haujlwm los tiv thaiv cov nquag overcurrent thiab overvoltage tripping
  • Ceev ceev kev txwv tsis pub muaj nuj nqi: Txo cov kev ua yuam kev thiab txhim kho cov txheej txheem ruaj khov
  • Lub Hwj Chim-ntawm Cov Khoom Siv Hluav Taws Xob Hluav Taws Xob Kev Nyab Xeeb Kev Ruaj Ntseg: Muaj peev xwm pom kev muaj kev nyab xeeb kom paub txog ntawm cov khoom siv hluav taws xob uas muaj zog xws li grounding, luv Circuit Court, thiab lwm yam.
  • Fais Fab-Thaum Tsis Siv Neeg Ua Haujlwm Pib Ua Haujlwm: Fais fab-nyob rau pib tsis siv neeg yog xaiv tau, kev ncua sijhawm yog kho tau.
  • Ib-rau-ob yam khoom siv dej ua haujlwm:Los ntawm kev koom tes ntawm software thiab beays, txoj haujlwm ntawm ib lub tshuab tsav ob lub twj muaj peev xwm pom tau
  • Tsis Siv Neeg Zog Txuag Kev Lag Luam:Cia li txo cov zis hluav taws xob nyob rau hauv lub teeb thauj mus los ua kom tiav lub zog-txuag cov nyhuv
  • Constant Siab Tswj Function:PID Kev Hloov Kho, PID REGISHACT DRICKING SAIB XYUAS, PID PW THIAB ROOB-UP
  • Antifrardze Ua Haujlwm:Qhov zaus, sijhawm, thiab lub voj voog tuaj yeem tsim tau rau cov tshuaj tiv thaiv kev tswj hwm
  • Dej xau Nrhiav tau:Txhim kho cov pw kom pw los tswj cov dej xau pov tseg kom pom cov coefficient

 

Tso saib thiab ua haujlwm keyboard

 

 

  • LED Zaub: tuaj yeem tso tawm cov lus pom zoo siab, phiaj xwm siab, kev ua haujlwm ntau, khiav haujlwm tam sim no thiab lwm cov ntaub ntawv
  • Parameter xauv haujlwm: txhais tau hais tias cov tsis raug kaw nyob rau hauv qhov khiav lossis kaw lub xeev kom tiv thaiv kev ua yuam kev

 

Kev Siv Ib puag ncig

 

 

  • Qhov chaw siv: Nyob sab hauv tsev, plua plav los ntawm tshav puam, cov roj corrosive, roj mist, qaug dej lossis ntsev, thiab lwm yam.
  • Qho siab: Hauv qab no 1000m; saum toj 1000m, siv nrog kev txheeb khoom, 1% rau txhua 100m nce ntxiv
  • Thaj kub cua sov: {-10 degree ~ 40%, 1% rau txhua 1% nce ntxiv ntawm qhov kub tshaj plaws, qhov kub siab tshaj plaws yog 50 degree
  • Kev vaum: 95% rh, zam kev hws
  • Kev co: Kev co kev ua kom nrawm yog tsawg dua 0. 6g
  • Cia kub: {-25 degree ~ +60} degree

 

Vaj huam sib luag vaj huam sib luag piav qhia

 

 

vfd drive manufacturers

  1. Daim qhia muaj zaub mov li cas: Siv hloov los ntawm cov qauv tas los hloov qauv.
  2. P.sp / ent: Shortcut tus yuam sij ntawm cov dej siab teeb tsa thiab "kev lees paub" cov ntsiab lus tseem ceeb.
  3. Txav: Siv los hloov cov zaub thiab txav cov cursors hauv parameter hloov .Ntiv cov xwm txheej, ua haujlwm "tuaj yeem hloov mus rau hauv qhov chaw, tso tawm tam sim no, kev tawm tswv yim thiab tswv yim siab. Nias "Hloov" rau hloov kho cov tsis muaj. Flicker Ntsis yog qhov tam sim no uas tuaj yeem hloov kho.
  4. ▲ Keys ▼: siv los hloov kho qhov ntsuas qhov tseem ceeb.
  5. Kev khiav: Pib khawm thaum siv cov keyboard li hom pib.
  6. Nres: Nres khawm thiab Txhaum Reset khawm thaum siv cov keyboard raws li hom pib.
  7. Tsa JOP: Siv nyob rau hauv lub debugging theem ntawm VFD, tshuab cov cuab yeej siv tau khiav ntawm nws tus kheej.
  8. Lub pob caus: Tig mus rau qhov rooj hloov pauv qhov teeb tsa siab

 

Qhov taw qhia lub teeb teeb:

 

  • Kev khiav: (Ib txwm nyob ntawm) kev qhia kev khiav; (Flicker): pw tsaug zog lossis nres
  • Nres: Nres lossis standby qhia
  • Nuj Nplaum: Kev Qhia Online: Thaum lub teeb nyob ntawm, kev sib txuas lus ua tiav.
  • Qhov ceeb toom: VFD Txhaum Tswb
  • Hz: Thaum lub teeb nyob ntawm, cov ntsiab lus ntawm cov zaub tau khiav.
  • A: Thaum lub teeb nyob ntawm, cov ntsiab lus ntawm cov zaub yog cov zis tam sim no.
  • V: Thaum lub teeb nyob ntawm, cov ntsiab lus ntawm cov zaub yog lub tsheb npav.
  • Teeb Bar: Thaum lub teeb ntawm cov zaus zaus thiab cov zis tam sim no yog nyob rau, cov ntsiab lus ntawm cov zaub yog ua ntej teeb tsa siab.
  • Sys bar: Thaum lub teeb ntawm cov zis tawm tam sim no thiab tsheb npav hluav taws xob yog nyob rau, cov ntsiab lus ntawm cov zaub yog ua ntej teeb tsa siab.

 

Tus qauv cov npe ntawm cov hluav taws xob zaus hloov kho

 

 

Tus qauv

Rated zog

(kw)

Lub Zog Muaj Zog

(KVA)

Input tam sim no

(A)

Khoom uas tsim tau lawm

(A)

kw Hp
Ib Leeg-Theem 220V
Pdg 10-2 sr75b 0.75 1.5 8.2 4.5 0.75 1
Pdg 10-2 s1r5b 1.5 3 14 7 1.5 2
Pdg 10-2 s2r2b 2.2 4 23 9.6 2.2 3
Peb-theem 380V
Pdg 10-4 tr75b 0.75 1.5 3.4 2.5 0.75 1
Pdg 10-4 t1r5b

1.5

3 5.0 3.8 1.5 2
Pdg 10-4 t2r2b
2.2 4 5.8 5.1 2.2 3
Pdg 10-4 t004b / 5r5p
4/5.5 5.9/8.9
10.5/14.6
9/13
4/5.5
5.5/7.5
Pdg 10-4 T5R5B / 7r5P
5.5/7.5
8.9/11
14.6/20.5
13/17
5.5/7.5
7.5/10
Pdg 10-4 t7r5b
7.5
11
20.5
17
7.5
10
Pdg 10-4 t011b / 015p
11/15
17/21
26/35
25/32
11/15
15/20
Pdg 10-4 T015B / 018r5p
15/18.5
21/24
35/38.5
32/37
15/18.5
20/25
Pdg 10-4 T018r5b / 022P
18.5/22
24/30
38.5/46
37/45
18.5/22
25/30
Pdg 10-4 T022B / 030p
22/30
30/40
46.5/62
45/60
22/30
30/40
Pdg 10-4 t030b / 037p
30/37
40/57
62/76
60/75
30/37 40/50
Pdg 10-4 T037b / 045p
37/45
57/69
76/92
75/91
37/45 50/60
Pdg 10-4 T045B / 055P
45/55
69/85
92/113
91/110
45/55 60/70
Pdg 10-4 T055B / 075P
55/75
85/114
113/157
112/150
55/75 70/100
Pdg 10-4 T075b / 093p
75/93
114/134
157/180
150/170
75/93 100/125
Pdg 10-4 t093b / 110p
93/110
134/160
180/214
170/210
93/110
125/150
Pdg 10-4 T110b / 132p
110/132
160/192
214/256
210/253
110/132
150/180
Pdg 10-4 T132B / 160p
132/160
192/231
256/307
253/304
132/160
180/220
Pdg 10-4 T160B / 185P
160/185
231/245
307/345
304/340
160/185
220/250
Pdg 10-4 t185b / 200p
185/200
245/260
345/385
340/377
185/200
250/275
Pdg 10-4 t200b / 220p
200/220
260/280
385/430
377/426
200/220
275/300
Pdg 10-4 t220b / 250p
220/250
280/355
430/468
426/465
220/250
300/340
Pdg 10-4 t250B / 280p
250/280
355/396
468/525
465/520
250/280
340/380
Pdg 10-4 t280b / 315p
280/315
396/445
525/590
520/585
280/315
380/430
Pdg 10-4 T315B / 35B / 355P
315/355
445/500
590/665
585/650
315/355
430/480
Pdg 10-4 T355B / 400B / 400B
355/400
500/565
665/785
650/725
355/400
480/545
Pdg 10-4 t400b
400
565
785
725
400 545

 

Ib txwm ua txhaum thiab kov

 

 

Tsis muaj zaub ntawm lub hwj chim rau
  • Tshawb xyuas seb cov phiaj xwm tawm hluav taws xob tau sib xws nrog cov nominal voltage ntawm kev tsav nrog multimeter.
  • Tshawb xyuas seb puas yog peb-theem Rectifier choj yog lawm. Yog tias tus choj ratifier tau tawg, thov thov kev pabcuam.

 

Lub zog huab cua hloov mus ncig ntawm lub hwj chim ntawm.
  • Tshawb xyuas seb puas muaj Circuit Court lossis av txuas ntawm cov hwj chim tawm. Yog tias muaj, thov tshem tawm nws.
  • Tshawb xyuas seb tus choj rectifier tau tawg tag. Yog tias muaj, thov thov kev pabcuam.

 

Lub cev muaj zog tsis tig tom qab VFD khiav.
  • Tshawb xyuas seb puas muaj cov khoom siv hluav taws xob sib npaug ntawm koj, V, W. Yog tias muaj, xyuas seb lub cev muaj zog lossis thaiv. Yog tias tsis yog, thov paub meej tias tus neeg muaj lub cev muaj zog tau teeb tsa kom raug.
  • Yog tias muaj cov zis tawm tab sis peb-theem zog tsis sib npaug, thov thov kev pabcuam.
  • Yog tias tsis muaj cov zis hluav taws xob, thov thov kev pabcuam.

 

Nws tsis nres nyob rau hauv tsis muaj dej siv.
  • Txheeb xyuas seb cov ntawv cim siab tso tawm ntawm VFD Board yog tsis muaj tsawg tshaj li teeb tsa. Yog tias lub tswv yim siab yog tsawg dua li teeb tsa lub siab, thov kosSeb ntau yam ntawm lub siab sensor tau teeb tsa kom raug, seb lub twj tso kua mis rotatesRov qab, txawm tias muaj huab cua thiab seb cov inlet yog thaiv los ntawm sundries.
  • Yog tias cov lus pom zoo hloov rov qab thiab txuas ib ncig ntawm cov nqi tsim, nres qhov ntsuas kom tsis kam lees lossis tsis txhob hloov lub cim ntsuas.

 

Nws tsis tuaj yeem pw hauv cov dej me me lossis dej xau
  • Yog tias nws tsis tsaug zog lossis pw tsaug zog ntev dhau lawm, thov txo tus nqi ntawm f 0. 04 kom zoo.
  • Yog tias nws pib thiab nres ntau zaus, thov nce tus nqi ntawm f 0. 04 kom zoo

 

Nws tsis tuaj yeem nres kom tiv thaiv hauv dej tsis txaus.
  • Dej tsis txaus tiv thaiv hloov chaw (F4. {00) tsis yog qhib.
  • Qhov ntsuas tus nqi ntawm cov dej tsis txaus (F4.01) tau teeb tsa tsawg.
  • Qhov feem pua ​​tam sim no ntawm cov dej tsis txaus (F4.04) tau teeb tsa qis dhau.

 

Kev ceev faj kev nyab xeeb ntawm cov hluav taws xob zaus hloov kho

 

 

Nruab ntawm eLottrical zaus hloov pauv

  • Thaum txhim kho lossis txav mus rau inverter, thov tuav hauv qab ntawm cov khoom siv tsuas yog tuav lub plhaub sab nraud kom tiv thaiv cov inverter los ntawm kev tsoo lossis puas.variable drive motor
  • Lub inverter yuav tsum tau ceev tseg ntawm cov khoom siv hluav taws xob thiab cov khoom tawg thiab cov cua sov, thiab teeb tsa ntawm nplaim taws retardants xws li hlau.
  • Thaum lub inverter tau teeb tsa hauv lub txee fais txee lossis lwmyam ntim, thiab lwm tus yuav tsum teeb tsa kom ntseeg tau tias qhov kub nyob hauv qab 40 degree. Txwv tsis pub, cov inverter yuav raug puas vim muaj qhov kub tshaj kub.

 

TxojNtawm Hluav Taws Xob Cov Hluav Taws Xob Hloov Cov Hluav Taws Xob

  • Cov xaim yuav tsum ua tiav los ntawm cov tsim nyog tshaj lij cov hluav taws xob engineers, txwv tsis pub muaj hluav taws xob lossis kev puas tsuaj rau lub inverter.
  • Nco ntsoov tias cov fais fab mov tau txiav ua ntej ua ntej pib hluav taws xob, txwv tsis pub nws yuav ua rau hluav taws xob lossis hluav taws.
  • Txwv tsis pub ua av qeeg yuav tsum tau ua kom zoo nkauj, txwv tsis pub cov nyob hauv tsev inverter yog qhov txaus ntshai kom muaj zog.
  • Tsis txhob kov lub davhlau ya nyob twg, thiab inverter cerrcuit Court davhlau ya dav hlau yuav tsum tsis txhob tiv tauj lub vaj tse, txwv tsis pub nws yuav ua rau hluav taws xob hluav taws xob.
  • Ua ntej tso zis, lees tias qhov ntsuas voltage thiab theem tus lej ntawm lub zog hluav taws xob thiab qib theem, txwv tsis pub nws yuav ua rau hluav taws lossis tus kheej.
  • Cov khoom siv hluav taws xob tsis tuaj yeem txuas nrog cov inverter tso zis tawm ntawm cov inverter thiab yuav tsis tsim nyog rau kev tiv thaiv kev tiv thaiv.
  • Lub inverter tsis tuaj yeem raug nrog withstand voltage sim, txwv tsis pub nws yuav ua rau kev puas tsuaj rau inverter.
  • Lub CALLENT Circuit Txwv xas xaim hluav taws xob xas xaim thiab kev tswj hwm hluav taws xob ntawm lub inverter yuav tsum tau sib cais lossis ntsug hla, txwv tsis pub tswj lub teeb liab yuav cuam tshuam nrog.
  • Cov xaim cable ntawm lub davhlau ya nyob twg yuav tsum tau siv ib lub qhov ntswg xaim nrog lub tes tsho insulating.
  • Thaum lub cable ntev ntawm inverter thiab lub cev muaj zog tshaj 50 meters, nws raug pom zoo kom siv cov tshuaj reactor los tiv thaiv cov inverter thiab lub cev muaj zog.

 